TS6000/300 Control Panel

Turbine Services TS6000 (suitable for Proven 6kW grid connect wind turbines)

Dimensions W H D, 300x400x200mm Mains isolator (rotary, lockable in the off position) Wind Turbine isolator (rotary, lockable in the off position) 3-phase rectifier (60Amp rating) Volt meter (analogue, easy to read) Ammeter (analogue, easy to read) DC cartridge fuse (complete with spare fuse). Door interlock for added safety (switch off to open) Pre drilled gland plate (4 x 20mm)

6kW Control Panel wiring diagram

Wind power comes in on three phases through a mechanical switch and a contactor before being rectified into DC power.  The DC power is then fed into a fuse ready for the inverter connection.  An ammeter and Voltmeter are also installed to help the user understand what is happening.  The 'Over Voltage Protection Device' senses two of the three phases from the wind turbine and activates the contactor when the Voltage is sufficiently low.  This device is mains powered. The second mains isolator is not shown on this diagram as it's not connected to anything in the panel.