banner











Control Panels

Turbine Services TS6000 (suitable for Proven 6kW grid connect wind turbines):

 
  • Dimensions W H D, 300x400x200mm
  • Mains isolator (rotary, lockable in the off position)
  • Wind Turbine isolator (rotary, lockable in the off position)
  • 3-phase rectifier (60Amp rating)
  • Volt meter (analogue, easy to read)
  • Ammeter (analogue, easy to read)
  • DC cartridge fuse (complete with spare fuse).
  • Door interlock for added safety (switch off to open)
  • Pre drilled gland plate (4 x 20mm)

Turbine Services TS15000 (suitable for Proven 15kW grid connect wind turbines):

 
  • Dimensions W H D, 300x400x200mm
  • Wind Turbine isolator (rotary, lockable in the off position)
  • 3-phase rectifier (60Amp rating)
  • Volt meter (analogue, easy to read)
  • Ammeter (analogue, easy to read)
  • DC cartridge fuse (complete with spare fuse).
  • Door interlock for added safety (switch off to open)
  • Pre drilled gland plate (4 x 20mm)

Turbine Services TSSE1500/48 (suitable for small water turbines, up to 10kW @ 24V or 48V):
 
  • Dimensions W H D, 300x400x200mm
  • Water Turbine isolator (Latching in the off position)
  • 3-phase rectifier (if required)
  • Volt meter (analogue, easy to read)
  • Ammeter (analogue, easy to read)
  • DC cartridge fuse (complete with spare fuse).
  • Pre drilled gland plate (4 x 20mm)
 

Turbine Services custom control panel.

 

We design and build control panels for all manner of systems.  The control panel shown here is for a 3-ph water turbine, off-grid system.

Please contact us if you would like to enquire about us designing, building or installing control panels.

 


Turbine Services TSG59Pro control panel.

For systems that generate in excess of 16Amps per phase, G59 regulations are employed.  The TSG59Pro control panel has a lid mounted G59 relay complete with LCD readout, which automatically disconnects the embedded generator from the national grid upon a mains fault using a large 3-phase contactor. A door interlock rotary isolator adds protection and allows a user to manually disconnect their embedded generation system.  Comes with 4x 20mm holes in the gland plate for easy connection on site.  A light is mounted along side the G59 relay giving the user a quick indication as to whether the system is grid connected or not.  Protects against

  • Voltage - under and over
  • Frequency - under and over
  • Vector shift - 1deg increments